ILD-600
Double Channel Vehicle Loop Detector

guardingaccessways or for counting vehicles.
The output signal can be used for controlling
door and gatedrive mechanisms, operating barriers,
controlling traffic light systems or activating card dispensers in parking lots.
It uses the advanced microprocessor technology,
and can work in diverse environments.
ILD-600 has two-way output relays.
One is unlimited output when loop is permanently covered,
while the other is multi-mode that can be set by users.



Technical data | ILD-600 |
---|---|
Operating voltages | 220V AC±10% |
Power consumption | < 5W |
Output | Relay output |
Frequency range | 20kHz to 170kHz (4 grades adjustable) |
Reaction time | 20 ms |
Sensitivity | 10 grades adjustable |
Loop inductance | Ideal 100~300µH (include connecting wiring) |
Loop conn. Wiring | Max 50µH~1000µH (include connecting wiring) |
Loop conn. Wiring | Max. 100m, twisted at least 20 times per meter, total resistance<10 |
Operating temp | -30℃ to +75℃ |
Storage temp | -40℃ to +85℃ |
Relative humidity | ≤ 95°C |
Connection | 11-pin socket |
Shell | PC + ABS engineering plastics |
Installation | DIN rail |
Dimensions | 110×60×100 mm (L×W×H) |
Net Weight | 400g (include socket) |