s k y p e

ILD-600

Double Channel Vehicle Loop Detector

Acess Pro Schranke

     Application     

    Parking Barrier Control  

    Vehicle Access Control 

    Motorised Gates and Doors 

    Industrial Control Systems

     

Features

CE compilation

Industrial grade design

LED indication

Low cost and easy to install

Automatic Frequency Selection


phone icon

+0086-755-86098563

datenblatt icon

PDF

Product pictures
Dimensional drawings
Design und Qualität Bild

Design und Qualität Bild

Design und Qualität Bild


Technical dataILD-600 
Operating voltages  220V AC±10%
Power consumption< 5W
OutputRelay output
Frequency range  20kHz to 170kHz (4 grades adjustable)
Reaction time20 ms
Sensitivity10 grades adjustable
Loop inductance Ideal 100~300µH (include connecting wiring)
Loop conn. WiringMax 50µH~1000µH (include connecting wiring)
Loop conn. WiringMax. 100m, twisted at least 20 times per meter, total resistance<10
Operating temp-30℃ to +75℃
Storage temp -40℃ to +85℃
Relative humidity ≤ 95°C 
Connection 11-pin socket
ShellPC + ABS engineering plastics
InstallationDIN rail
Dimensions110×60×100 mm (L×W×H)
Net Weight 400g (include socket)